Hot New Products What Is A Hose Coupling Used For - Pipe Joint Bypass Filter Group-BK Series – Vega Electronic

Short Description:

Pipe Joint Bypass Filter Group-BK Series Specifications Type: Offline high-pressure oil return bypass filter Materials:Micro-glass fiber Accuracy:<3μm Filter Area :0.316㎡ Inlet Pressure: 0.7~32Mpa Return Pressure: T≤0.5MPa (Only with differential pressure indicator model) Filter Flux: Max 3 L/Min Operating Temperature:-20~120 ℃ Working Viscosity: 1~680 cSt Pressure Alert:0.21MPa Filter Weight:2 Kg Port size:Inlet P-1/4 PT Flux:≤2L/Min Return:T-1/4 PT Flux: >2L/Min Return:T-3/8 PT Fea...


Product Detail

Product Tags

Related Video

Feedback (2)

Being supported by an highly developed and specialist IT team, we could give technical support on pre-sales & after-sales service for Rubber Injection Machine , Injection Molding Machine Aluminium , Plastic Injection Moulding Machine Parts , Together with the everlasting target of "continuous top quality improvement, customer satisfaction", we have been sure that our products high quality is stable and trustworthy and our solutions are best-selling at your home and overseas.
Hot New Products What Is A Hose Coupling Used For - Pipe Joint Bypass Filter Group-BK Series – Vega Electronic Detail:

Pipe Joint Bypass Filter Group-BK Series
Specifications
Type: Offline high-pressure oil return bypass filter
Materials:Micro-glass fiber
Accuracy:<3μm
Filter Area :0.316㎡
Inlet Pressure: 0.7~32Mpa
Return Pressure: T≤0.5MPa (Only with differential pressure indicator model)
Filter Flux: Max 3 L/Min
Operating Temperature:-20~120 ℃
Working Viscosity: 1~680 cSt
Pressure Alert:0.21MPa
Filter Weight:2 Kg
Port size:Inlet P-1/4 PT
Flux:≤2L/Min Return:T-1/4 PT
Flux: >2L/Min Return:T-3/8 PT
Features
Glass fiber filter , never deformation and metamorphism
Inlet port anti-clogging design, ensure long-term filtration work
Differential pressure alarm shows the filter life clearly
Flow control stability, filter effect significantly
Small,light and easy to install
Large filter area ﹑ more pollutants ﹑ long filter life.
Easy to maintain and replace the filter jar
INSTRUCTIONS
Applicable to mineral oil &hydraulic oil, lubricants and so on.
Installation of self-high pressure and return hose and its joints, in order to reduce the back pressure ,the oil return pipe hole diameter no less than 8mm, the length within 2 meters is better.
With differential pressure indicator alarm device filter outlet T, available pressure pipe directly connected to the oil valve plate return oil T port
, Only pay attention to oil valve plate T oil pressure is not exceed 0.5MPa.
Pressure gauge filter outlet T tubing only available in the rated flow without back pressure connected. Replace the filter tank when the pressure gauge shows 2.5 bar or change the filter tank every year on time.
Please follow the instructions printed on the jar when making replacement.
Please treatment for environment protection when abandoned the obsolete jars.
Product description
Flow Control Valve
Oil pressure changes, the stability of the control oil to the constant rated flow
Differential Pressure Indicator
Visual or electronically controlled indicator is not affected by the back pressure,when the filter element need to be replace it will output signal correctly.
Fixed Support
Easy to install in filter
Bracket Lock Net
The filter can be fixed on the bracket at the swing angle.
Filter Tank
Rotary filter easy replace
Bypass valve
Protect the filter when the up-down over-pressure bypass oil return tank
Precision glass fiber filter element
Glass fiber filter folded structure provides maximum dirt holding area, and difficult to deformation and metamorphism, long-term durability.
Dynamic filter spool
≥0.8mm solid particles are stopped to take in the former, prevented from entering the flow control valve blockage.
Hydraulic instructions
Flux Demand:
For the system of high pressure or oil return filter has pressure loss;And bypass filter has flux loss.There is a difference between the two.Especially the smaller flow oil pump system,when use the bypass filter should insure the suitable flux to avoid the working flux insufficient.
Take Oil Point:
Oiling point must be the early part of the system pressure at a high pressure, high pressure hose or pipe connections available, and take place the following optional:
1.Oil out of point
2.Oil valve plate system pressure point
3.System pressure valve pressure sampling point
Attention:between the oil point and the filter can be considered the configuration needle valve, it is easy to replace the tank no need the machine pause.
Oil return point:
The choice of oil return and tubing configuration directly affect the efficiency of the filter, it can lead to leakage of oil or even misuse of filter life, the best is the filter back to the port at zero pressure.
1.the return point of oil groove.
2.the return point of oil valve plate(not suitable for the filter with pressure gage.)
Indicator information
Electronically controlled type :
output mode single contact (normally open)
Contact load 10W/100Vdc 0.5A Max
Visual function red LED(only for S4&S5 option)
Power 24-36Vdc (only for S4&S5 option)
Output pressure 0.19-0.21MPa
Operating temperature -20℃-120℃
Insulation method water-proof
Electrical connection DIN43650 plug
Visual type:
Output mode mechanical blue to red indicator
Output pressure 0.19-0.21MPa
reset function Automatic reset
operating temperature -20℃-90℃
Insulation method show point water-proof
Mounting Dimension:
5555
Filter Option
BK04 – 030 – F – B – N – 10 – X -S*
1 2 3 4 5 6 7
Filter Element Number: SP01-030-F
Filter Fineness 030 – 3μm(Please contact supplier for the others)
Material F- micro-glass fibres
Bypass pressure B – 0.25MPa
Rubber seal N- butyronitrile ;V-fluorine
Design number 10
Flux number X-1.5l/min;Y-2l/min;Z-3l/min(Please contact supplier for the others.)
Alarm Configuration S1-pressure gage ;S2-visual;S3-electric contact;
S4-electric contact with light(OV concurrent);S5-electric contact with light(+24V concurrent)


Product detail pictures:

Hot New Products What Is A Hose Coupling Used For -
 Pipe Joint Bypass Filter Group-BK Series – Vega Electronic detail pictures


Related Product Guide:
Mercury Marine introduces new V8, V6 engine models | Hydraulic Gauges
JPT Digital Image Correlation: A New Way To Look at Hydraulic Fracturing | Rotary Injection Molding Machine

Sticking for the basic principle of "Super Top quality, Satisfactory service" ,We've been striving to be an excellent business enterprise partner of you for Hot New Products What Is A Hose Coupling Used For - Pipe Joint Bypass Filter Group-BK Series – Vega Electronic, The product will supply to all over the world, such as: Hungary , Florida , Peru , We are very responsible for all details on our customers order no matter on warranty quality, satisfied prices, quick delivery, on time communication, satisfied packing, easy payment terms, best shipment terms, after sales service etc. We provide one-stop service and best reliability to our every customers. We work hard with our customers, colleagues, workers to make a better future.
  • This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Mike from Czech Republic - 2015.06.26 19:27
    The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Astrid from Lebanon - 2016.01.28 19:59

    Related Products